Temperature Range (℃) | -20℃, -40℃, -70℃, -80℃ ~ 200℃. |
---|---|
Test Cabinet Dimensions W×D×H (mm) | 400×400×300 500×500×300 600×600×300 |
Thermal Shock Range (℃) | 0℃, -20℃, -40℃. -60℃ ~ 80℃, 100℃, 150℃. |
Temperature Control System | The New Import LCD 5.7 Inch TFT LCD Touch Controller |
Inner Material | SUS#304 Stainless Steel. |
Temperature Range (℃) | -20℃, -40℃, -70℃, -80℃ ~ 200℃. |
---|---|
Test Cabinet Dimensions W×D×H (mm) | 400×400×300 500×500×300 600×600×300 |
Thermal Shock Range (℃) | 0℃, -20℃, -40℃. -60℃ ~ 80℃, 100℃, 150℃. |
Cooling System | Air-cooled Or Water-cooled |
Temperature Control System | The New Import LCD 5.7 Inch TFT LCD Touch Controller |
Temperature Range (℃) | -20℃, -40℃, -70℃, -80℃ ~ 200℃. Option |
---|---|
Test Cabinet Dimensions W×D×H (mm) | 600×600×300 |
Thermal Shock Range (℃) | 0℃, -20℃, -40℃. -60℃ ~ 80℃, 100℃, 150℃. |
Temperature Control System | The New Import LCD 5.7 Inch TFT LCD Touch Controller |
Inner Material | SUS#304 Stainless Steel. |
Test Cabinet Material | SUS#304 Stainless Steel |
---|---|
Refrigeration System | Dualistic Formula System |
Cooling Method | Water Cooling Or Air Cooling |
High Temperature Shocking | +60℃~+150℃ |
Low Temperature Shocking | -10℃~-65℃ |
Low Temperature Shocking | -10℃~-65℃ |
---|---|
Output Mode | PID+PWM+SSR Control Mode |
Cooling Method | Cooling Method: |
High Temperature Shocking | +60℃~+150℃ |
Packaging Details | Wooden Case |
Test Cabinet Material | SUS#304 Stainless Steel Material |
---|---|
Refrigeration System | Dualistic Formula System |
Cooling Method | Water Cooling Or Air Cooling |
High Temperature Shocking | +60℃~+150℃ |
Low Temperature Shocking | -10℃~-65℃ |
Item Name | 3 Box Type Thermal Shock Test Chamber |
---|---|
Chambers | High Temperature Chamber,low Temperature Chamber, Specimen Chamber |
Test Space | 400×350×350mm,500×500×400mm,600×500×500mm,700×600×600mm, |
Temperature Range | -20℃、-40℃、-70℃、-80℃~250℃ |
Impact Range | 0℃、-20℃、-40℃、-60℃~80℃、100℃、150℃、 |
Item | Ozone Resistance Aging Test Chamber |
---|---|
Inner Size | 500×500×400mm, D×W×H |
Temperature Range | 0℃~70℃ |
Humidity Range | 40%~98%R.H, |
Ozone Concentration | 10~500pphm |
Item | Hot Cold Impact Tester |
---|---|
Test Cabinet Dimension | 400×400×300mm, 500×500×300mm,600×600×300mm |
Temperature Range | -20℃、-40℃、-70℃、-80℃~200℃ |
Impact Range | 0℃、-20℃、-40℃、-60℃~80℃、100℃、150℃、 |
Heating Rate | 3℃~5℃/min (no Load) |
Cooling Method | Water Cooling Or Air Cooling |
---|---|
Controller | Programmable |
Output Mode | PID+PWM+SSR Control Mode |
Recovery Time | ≤5min |
Temperature Range(℃) | -20℃、-40℃、-70℃、-80℃~250℃ |