Item Name: Walk In Climatic Test Chamber
Innner Size: 2000*2000*2000 Mm (W*D*H)
Outer Size: About 2300*4200*2380 Mm (W*D*H), Refer To Designed Size
Weight: About 2800kg
Temperature Range: -60℃→+120℃
Humidity Range: 20%~98%R.H
High Light:

Walk In Environmental Climatic Test Chamber

,

Laboratory Environmental Climatic Test Chamber

,

8 Cubic Climatic Test Chamber

Basic Infomation
Place of Origin: China
Brand Name: POOTAB
Certification: ISO,CE,SGS
Model Number: PT-2100-8000
Payment & Shipping Terms
Packaging Details: Packed in a whole container for sea boat
Delivery Time: 100 sets per month
Payment Terms: T/T, L/C, Western Union
Product Description

Walk In Environmental Climatic Test Chamber For Laboratory 8 Cube Temperature Humidity Test Room

 

Usage :

Walk In Type Programmable Constant temperature humidity environmental test chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.
The simulated products are tested under the combination of temperature and humidity in the climatic environment (high and low temperature operation & storage, temperature cycle, high temperature and high humidity, low temperature and low humidity, condensation test, etc.) to check whether the adaptability and characteristics of the product itself change.Must meet the requirements of international standards (IEC, JIS, GB, MIL...) to achieve international measurement procedure consistency (including test procedures, conditions, methods).

 

Specifications :

Model

PT-2100-8000 Walk In Environmental Climatic Test Chamber For Laboratory 8 Cube Temperature Humidity Test Room
1.1 Innner Size 2000*2000*2000 mm (W*D*H)
1.2 Outer Size About 2300*4200*2380 mm (W*D*H), refer to designed size
1.3 Weight About 2800kg

Performance

( refer to condition of the water-cooled water temperature of 25℃, without specimen)

 

2.1 Environmental conditions

Temperature 5-35℃,relative humidity≤90%(when 25℃)

 

2.2 Power Supply

AC 380V,50Hz,3 phase 4W+ground wire

(grounding resistance < 4 Ω)

2.3 Temperature Range -60℃→+120℃
2.4 Temperature Resolution 0.01℃
2.5 Temperature Fluctuation ≤±0.5℃
2.6 Temperature Deviation ≤±2℃
2.7 Temperature Uniformity ≤±2℃
2.8 Heating Rate

≥ 2℃/ min, nonlinear (no load)

+20℃→+120℃ ≤50 min (no load)

2.9 Cooling Rate

≥ 2℃/ min, nonlinear (no load)

+20℃→-60℃ ≤40 min (no load)

2.10 Humidity Resolution 0.1%R.H
2.11 Humidity Range 20%~98%R.H

 

 

 

 

2.12 Humidity Fluctuation

 

 

 

 

±2.5%R.H.

2.13 Humidity Deviation

When >75%RH:≤±2,3%RH,

When<75%RH:≤±5%RH

 

Walk In Climate Test Chamber Meet Standards :

IEC6008-2-1-2007

GB/T 2423.2-2008

GB/T5170.18-2005

GB/T10586-2006

GB/T 10589-2008

GB/T2423.3-93(IEC68-2-3) Test Ca

 

Walk In Temperature Humidity Test Room Reference Pictures: 

Walk In Environmental Climatic Test Chamber For Laboratory 8 Cubic 0

 

Walk In Type Environmental Chamber Applications :

Walk In Environmental Climatic Test Chamber For Laboratory 8 Cubic 1

 

Spare Parts Of The Machine :

Walk In Environmental Climatic Test Chamber For Laboratory 8 Cubic 2Walk In Environmental Climatic Test Chamber For Laboratory 8 Cubic 3           Walk In Environmental Climatic Test Chamber For Laboratory 8 Cubic 4

refrigerating compressor                                                evaporator                                                     refrigeration accessory

 

Recommended Products
Get in touch with us
Contact Person : Michael Chan
Tel : +8613925771883
Fax : +86-769-85818236
Characters Remaining(20/3000)