| Standards | GB/T2423, GB/T5170, GB/T10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 |
|---|---|
| Humidity Range | 20% To 98%R.H |
| Temperature Range | -20℃ ~ 150℃, -40℃ ~ 150℃, -70℃ ~ 150℃, |
| Inner Material | SUS#304 Stainless Steel |
| Inner Cabinet (mm) | 500mm*500*600mm (150 Liters) |
| Item | Ozone Resistance Aging Test Chamber |
|---|---|
| Inner Size | 500×500×400mm, D×W×H |
| Temperature Range | 0℃~70℃ |
| Humidity Range | 40%~98%R.H, |
| Ozone Concentration | 10~500pphm |
| Standard | GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 |
|---|---|
| Regular Humidity Range | 20%R.H ~ 98%R.H |
| Temperature Range | -20℃ ~ 150℃(lowest About -70℃) |
| Inner Material | SUS#304 Stainless Steel. |
| Outer Material | Spray Color Galvanized Steel Sheet. |
| Temperature Range | +15℃~+70℃ |
|---|---|
| Temperature Uniformity | ≤±2℃ |
| Standards | IEC 60068-2-11 Test Ka:Salt Mist GB/T2423.17-2008 Test Ka:Salt Mist GJB150.11A-2009 GB/T10125-1997 GB/T5170.8 |
| Test Time | 1~999(S、M、H)adjustable |
| Saturation Drum Temperature | Room Temperature +5℃~+60℃ |
| Corresponding Standard | GB11158 , GB10589-89, GB10592-89, GB/T10586-89 GB/T2423.22-2001 GB/T2423.1-2001 GB/T2423.2-2001 GB/T2423.3-93 GB/T2423.4-93 ,ASTM D1735, IEC60068-2-1.1990, IEC60068-2-2.1974 , IEC 68-2-30 IEC68-2-0 |
|---|---|
| Test Item | NSS ,CASS,,ASS, SS, |
| Temperature Range | Room Temperature To 55℃ |
| Test Space | 45×60×40cm, 60×90×50cm, 70×100×50cm,100×120×50cm,100×160×50cm,100×120×60cm |
| Timer | Adjustable 0.1-999 Hours |
| Corresponding Standard | GB11158 , GB10589-89, GB10592-89, GB/T10586-89 GB/T2423.22-2001 GB/T2423.1-2001 GB/T2423.2-2001 GB/T2423.3-93 GB/T2423.4-93 ,ASTM D1735, IEC60068-2-1.1990, IEC60068-2-2.1974 , IEC 68-2-30 IEC68-2-0 |
|---|---|
| Test Item | NSS ,CASS,,ASS, SS, |
| Temperature Range | Room Temperature To 55℃ |
| Test Space | 45×60×40cm, 60×90×50cm, 70×100×50cm,100×120×50cm,100×160×50cm,100×120×60cm |
| Timer | Adjustable 0.1-999 Hours |
| Corresponding Standard | GB11158 , GB10589-89, GB10592-89, GB/T10586-89 GB/T2423.22-2001 GB/T2423.1-2001 GB/T2423.2-2001 GB/T2423.3-93 GB/T2423.4-93 ,ASTM D1735, IEC60068-2-1.1990, IEC60068-2-2.1974 , IEC 68-2-30 IEC68-2-0 |
|---|---|
| Test Item | NSS ,CASS,,ASS, SS, |
| Temperature Range | Room Temperature To 55℃ |
| Test Space | 45×60×40cm, 60×90×50cm, 70×100×50cm,100×120×50cm,100×160×50cm,100×120×60cm |
| Timer | Adjustable 0.1-999 Hours |
| Capacity Options | 200kg ,500kg,1000kg,2000kg |
|---|---|
| Temperature Range | -20℃、-40℃、-60℃~150℃ |
| Special Design | With Visual Window, Lighting |
| Test Stroke | Max 450mm, Not Including Gripper |
| Test Speed Range | 0.5 ~ 1000mm/min, Can Be Set. |
| Capacity | 200、500 、1000、2000 Kgf Choose One |
|---|---|
| Temperature Range | -20℃、-40℃、-60℃ To 150℃ |
| Humidity Range | 20%R.H~98%R.H |
| Test Speed | 0.5~1000mm/min,free Set |
| Test Stroke | Max 450mm |
| Inner Size | 80*80*80cm,etc |
|---|---|
| Metal Screen Wire Diameter | 50 Um |
| Power | Electronic, 380VAC 50HZ |
| Outer Dimension | 1130*1250*1650mm |
| Port | Shenzhen |